Download Print this page

GRAPHTEC CE6000 SERIES User Manual: Error Messages In Gp-gl Command Mode

Graphtec ce6000 series cutting plotter.
Hide thumbs

Advertisement

Error Messages in GP-GL Command Mode

Error
LCD Display
Displayed
E02001
E02004
E02005
E02006
Cause
The plotter received an unrecognizable
command.
Noise came in when the computer was
turned on.
The software configuration regarding the
output device has been changed.
The plotter's interface conditions have
changed.
A command was received containing
numeric parameters that exceed that
command's permissible range.
The software configuration regarding the
output device has been changed.
The plotter's interface conditions have
changed.
An error occurred in the receipt of data
within the interface.
The software configuration regarding the
output device has been changed.
The plotter's interface conditions have
changed.
The data out of cutting range has been
received.
13-6
Solution
Press the [ENTER] key.
Configure to drive the plotter from the menu
of the software.
Reset the interface settings of the software.
Reset the interface settings of the plotter.
Configure to drive the plotter from the menu
of the software.
Reset the interface settings of the software.
Reset the interface settings of the plotter.
Configure to drive the plotter from the menu
of the software.
Reset the interface settings of the software.
Reset the interface settings of the plotter.
Check the data.
Check the size of media and the cutting
range.
Check the magnification setting.
Check the step size settings.

Advertisement

Troubleshooting

   Also See for GRAPHTEC CE6000 SERIES

Comments to this Manuals

Symbols: 0
Latest comments:
  • Jishad Jan 10, 2018 08:16:
    my graphtec ce 6000-60 showing an error message
    Hardware illegal code. Can you solve this
  • sina oyekunle Dec 21, 2017 02:44:
    my graphtec ce 6000-60 showing an error message: check cam_b-pcb
  • jitendra solanki Jun 14, 2017 05:31:
    i want ce6000 series user manual pdf file