Error Messages For Arms - GRAPHTEC FC8000 Series User Manual

Cutting pro
Hide thumbs Also See for FC8000 Series:
Table of Contents

Advertisement

Error Messages for ARMS

Symptom
LCD Display
E04001
E04002
E04003
E04004
E04005
E04006
E04007
E04008
E04009
E04010
Possible Cause
Tilt to adjust with AXIS
ALIGNMENT is too large.
It is over the setting range of the
distance adjust.
Failed to adjust the sensor level.
It is over the setting range of the
distance adjust.
Could not scan the registration
marks.
Amount of data has exceeded the
I/O buffer size for the segment
area registration mark.
T est pattern plotting position is not Move the media toward center
within the plotting area for sensor
position adjustment.
Media end was detected while
detecting the registration mark.
It has exceeded detection area
while detecting the registration
mark.
It has exceeded detection area
while detecting the registration
mark.
13-9
Solution
Reload the media.
Reset to smaller value.
This media cannot be used.
Reset to smaller value.
Check the registration scan
position.
Decrease the data.
and plot the test pattern.
Check the media. Check the print
position of the registration mark.
Check the media. Check the print
position of the registration mark.
Check the media. Check the print
position of the registration mark.