6
Press the [3] key (TEST ARMS SENSOR).
TEST ARMS SENSOR screen is displayed.
7
Press either the [1] key (TYPE 1) or the [2] key (TYPE 2)
depending on the type of the registration mark to be used.
Following message is displayed.
8
Move the tool to the position to start scanning of the
registration mark by pressing the POSITION (
MARK TYPE 1
Move the tool inside this area
9
Confirm the position of the tool and press the [ENTER] key.
The plotter will automatically detect the registration mark and cut the
peak of each registration marks.
10
Confirm the cutting result.
See "Adjusting for the Registration Mark Scan Position"
adjust if the cutting position is shifted. See "Adjusting the Sensor Level"
and adjust if the registration mark cannot be scanned.
P.5-20
Registration mark scan area
) key.
MARK TYPE 2
Move the tool inside this area
and
P.5-27
5-25
Supplement
It will return to ARMS SETTING screen (4/4)
without changing the settings when you press
the [3] key (CANCEL).
Supplement
It will return to TEST ARMS SENSOR screen
without changing the settings when you press
the [4] key (CANCEL).
Supplement
Following error is displayed when the
registration mark was not scanned properly.
Press the [1] key (SCAN AGAIN) to scan again,
or the [2] key (CANCEL) to exit.

Advertisement

Troubleshooting

   Also See for GRAPHTEC CE6000 SERIES

Comments to this Manuals

Symbols: 0
Latest comments:
  • Jishad Jan 10, 2018 08:16:
    my graphtec ce 6000-60 showing an error message
    Hardware illegal code. Can you solve this
  • sina oyekunle Dec 21, 2017 02:44:
    my graphtec ce 6000-60 showing an error message: check cam_b-pcb
  • jitendra solanki Jun 14, 2017 05:31:
    i want ce6000 series user manual pdf file