Stop Cutting
Operation
1
Press the [PAUSE/MENU] key.
Operation will stop and following screen is displayed.
2
Press the [2] key (QUIT JOB).
Following screen is displayed.
3
Confirm if the data transfer from the computer is stopped and
press the [1] key (YES, CLEAR).
Following screen is displayed, the buffer memory is cleared, and it will
return to default screen.
READY screen
(Normal mode)
READY screen
(Simple mode)
3-13
Supplement
It will resume cutting by pressing [1]
(CONTINUE JOB) key.
See "Pause and Resume Cutting"
Supplement
It will return to operation stop screen
without clearing buffer memory when [2] key
(CANCEL) is pressed.
In the case that the operation is interrupted
and the buffer is cleared, make sure that the
data transfer is stopped.
If the data transfer continues, abnormal
operations where data is processed from the
middle may occur.
.
P.3-12