Error Messages in HP-GL Command Mode

If any of the following command errors occur, they are nearly always caused by following 2 reasons.
1. The configuration regarding the output device in the application software has changed.
2. The plotter's interface conditions have changed.
Perform following if these are the cause of the problem.
1. Reconfigure the output device of the application software to the plotter.
2. Reconfigure the plotter's interface conditions.
Error
LCD Display
Displayed
E03001
Error 1
E03002
Error 2
E03003
Error 3
E03005
Error 5
E03006
Error 6
E03007
Error 7
E03010
Error 10
E03011
Error 11
E03012
Error 12
E03013
Error 13
Cause
An unrecognizable instruction was
executed.
Wrong number of parameters were
specified.
An unusable parameter was executed.
An unusable character set was specified.
Coordinates of command specified out of
cutting area.
The data being input exceeds the capacity
of the plotter's downloadable character
buffer, polygon buffer, etc.
Other output command was executed while
executing an output command.
An invalid byte was received after ESC
code.
Invalid byte was received within device
control command.
A parameter outside of the permissible
range was specified in the I/O related
command.
13-7
Solution
Execute a recognizable command.
Execute the command with the correct
number of parameters.
Execute a recognizable parameter.
Specify usable character set.
Execute coordinates within the cutting area.
Adjust the buffer size.
Check the program.
Check the program.
Check the program.
Check the program.