Arms Error Messages - GRAPHTEC CE7000 Series User Manual

Cutting plotter
Table of Contents

Advertisement

ARMS Error Messages

Error
LCD Display
Displayed
E04001
E04004
E04005
E04006
E04007
E04008
E04009
E04010
E04011
Cause
Tilt to adjust with AXIS ALIGNMENT is too
large.
It is over the setting range of the distance
adjust.
Could not scan the registration marks.
Amount of data has exceeded the I/O
buffer size for the segment area registration
mark.
Test pattern plotting position is not within
the plotting area for sensor position
adjustment.
Media end was detected while detecting
the registration mark.
It has exceeded detection area while
detecting the registration mark.
It has exceeded detection area while
detecting the registration mark.
It has exceeded detection area while
detecting the registration mark.
15-9
Solution
Reload the media.
Reset to smaller value.
Check the registration scan position.
Decrease the data.
Move the media toward center and plot the
test pattern.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.
Check the media. Check the print position
of the registration mark.