Arms Error Messages - GRAPHTEC CE LITE-50 Service Manual

Cutting plotter
Hide thumbs Also See for CE LITE-50:
Table of Contents

Advertisement

9.6

ARMS Error Messages

Error
LCD Display
Code
E04001
E04002
E04003
E04004
E04005
E04006
E04007
E04008
E04009
E04010
E04011
CE LITE-UM-251-9370
Cause
Tilt with AXIS ALIGNMENT is too
large.
Distance adjustment value
exceeds the setting range.
Failed to adjust the sensor level. This media cannot be used.
Distance adjustment value
exceeds the setting range.
Could not scan the registration
marks.
Amount of data has exceeded
the I/O buffer size for the
segment area registration mark.
Test pattern plotting position is
not within the plotting area for
sensor position adjustment.
Detected the media end while
detecting the registration mark.
Exceeded detection area while
detecting the registration mark.
Exceeded detection area while
detecting the registration mark.
Exceeded detection area while
detecting the registration mark.
9-6
9 TROUBLESHOOTING
Solution
Reload the media.
Reset to smaller value.
Reset to smaller value.
Check the registration scan
position.
Decrease the data size.
Move the media toward center
and plot the test pattern.
Check the media.
Make sure the print position of
the registration mark.
Check the media.
Make sure the print position of
the registration mark.
Check the media.
Make sure the print position of
the registration mark.
Check the media.
Make sure the print position of
the registration mark.