8.4.4

Error Messages on ARMS

Error
Error Display
code
E04001
E04003
E04004
E04005
E04006
E04007
E04008
E04009
E04010
E04011
E04012
FC8600-UM-251-9370
Cause
Tilt to adjust with AXIS
ALIGNMENT is too large.
Failed to adjust the sensor
level.
It is over the setting range of
the distance adjust.
Could not scan the registration
marks.
Amount of data has exceeded
the I/O buffer size for the
segment area registration
mark.
Test pattern plotting position is
not within the plotting area for
sensor position adjustment.
Media end was detected while
detecting the registration mark.
It has exceeded detection area
while detecting the registration
mark.
8-9
8
TROUBLESHOOTING
Solution
Reload the media.
This media cannot be used.
Reset to smaller value.
Check the registration scan position.
Decrease the data.
Move the media toward center and
plot the test pattern.
Check the media. Check the print
position of the registration mark.
Check the media. Check the print
position of the registration mark.