2.12.2 Origin Point Settings When configuring HP-GL (Simple mode)
When using the HP-GL command, the origin point is set to either the lower left of the cutting area or the center.
When using the GP-GL command, this setting does not affect the operation.
Command settings are automatic in Simple mode.
This can also be set in Normal mode.
Supplement
See "Settings of Controls from Computer"
Operation
1
Press [PAUSE/MENU] key.
MENU screen is displayed.
2
Press [2] key (I/F).
INTERFACE screen is displayed.
3
Press [1] key (HP-GL ORIGIN POINT).
HP-GL ORIGIN POINT setting screen is displayed.
4
Press [1] key (LOWER LEFT) or [2] (CENTER).
5
Confirm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to INTERFACE screen.
6
Press [PAUSE/MENU] key.
It will return to default screen.
for more information.
P.11-1
2-55
Supplement
Press the POSITION ( ) key to return to the
interface menu without changing any settings.