CHAPTER 13 TROUBLESHOOTING
9.5 Position of the Multifeeder Pickup Latching Solenoid (SL6)
Slide the solenoid into the direction of A to adjust so that the gap between the shutter [1] and
the shutter plate [2] is 0.4 ±0.2 mm when the solenoid is pulled.
A
Figure 13-D214a
[2]
[1]
Figure 13-D214b
13-28
COPYRIGHT © 1999 CANON INC.