8) Slide out the process unit [7] as far as pos-
sible; while holding the grips, detach it by
lifting it.
Caution:
When placing the process unit after re-
moval, rotate the kit support plate [1]
counterclockwise so as to keep a dis-
tance from the floor.
Points to Note When Removing
the Photosensitive Drum
[1] When you have removed the photo-
sensitive drum, do not rotate the
magnet roller of the cleaner unit.
Doing so could cause leakage of
toner.
[2] When removing the photosensitive
drum or mounting it, do not rotate it
counterclockwise to avoid bending
of the blade.