Mounting The Corona Assemblies - Canon ImageRunner 600 Service Manual

Hide thumbs Also See for ImageRunner 600:
Table of Contents

Advertisement

CHAPTER 11 INSTALLATION
D.

Mounting the Corona Assemblies

No.
1
Remove the screw, and detach the front
cover of the transfer separation charging
assembly.
2
Remove the metal fixing (1 screw), and
disconnect the connector.
While pressing down on the front and the
rear of the transfer separation charging
assembly, pull it to the front then to the
upper left to remove.
Use alcohol solution, and clean the
transfer separation charging wire.
3
Mount the transfer separation charging
assembly with the following in mind:
• The charging assembly must be
completely dry.
• The charging wire cleaning member is
at the center.
• The gut wire is not forced against the
transfer guide.
• The grounding plate is positioned on the
outside of the frame. (See the diagram
on the right.)
4
Connect the connector of the transfer
separation charging assembly, and mount
the metal fixing.
5
Mount the front cover of the transfer
separation charging assembly with a
screw.
Push in the fixing/feeding assembly until
it locks in place.
11-10
COPYRIGHT © 1999 CANON INC.
Work
Remarks
Screw
Front cover of the transfer separation
charging assembly
Metal fixing
Charging assembly
Grounding plate
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Screw
Connector

Advertisement

Table of Contents
loading

Table of Contents