E060; E063 - Canon ImageRunner 600 Service Manual

Hide thumbs Also See for ImageRunner 600:
Table of Contents

Advertisement

CHAPTER 13 TROUBLESHOOTING
20

E060

Cause
Step
Connector
Connector
Primary
charging wire
cleaner home
position
detecting switch
(MSW4)
Primary
charging wire
cleaner motor
(M8)
DC controller
PCB
21

E063

Cause
Step
Connector
Connector
Transfer/
separation
charging wire
cleaner home
position
detecting switch
(MSW6)
Transfer/
separation
charging wire
cleaner motor
(M9)
DC controller
PCB
13-90
COPYRIGHT © 1999 CANON INC.
1
Are the connectors of the primary
charging assembly connected securely?
2
Is the connector (J502) of the DC
controller PBC connected securely?
3
Is the mounting of the primary charging
cleaner home position detecting switch
and the connection of the cable normal?
4
Replace the primary charging wire
cleaner motor (M8). Is the problem
corrected?
1
Are the connectors of the transfer/
separation charging assembly connected
securely?
2
Is the connector (J509) on the DC
controller PCB connected securely?
3
Is the mounting of the transfer/separation
charging wire cleaner home position
detecting switch and the connection of the
cable normal?
4
Replace the transfer/separation charging
wire cleaner motor (M9). Is the problem
corrected?
Checks
Checks
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Yes/No
Action
NO
Connect the connectors
securely.
NO
Connect it securely.
NO
If normal, replace the
switch.
YES
End.
NO
Replace the DC
controller PCB.
Yes/No
Action
NO
Connect the connectors
securely.
NO
Connect the connector
securely.
NO
If normal, replace the
detecting switch.
YES
End.
NO
Replace the DC
controller PCB.