Controlling the Developing Bias

The developing bias is controlled for the following:
[1] DC bias constant voltage
[2] AC bias constant voltage
When '1', developing
AC bias is generated.
J510A
1
HVDC-EN
2
3
4
5
6
7
DEV-AC-ON
8
DEV-DC-CNT
9
10
11
12
13
14
15
16
A voltage input between 0
and 12 V, used to control the
voltage level of the
developing DC bias.
Figure 6-404 Construction of the Control System
COPYRIGHT © 1999 CANON INC.
Relay PCB
1 2 3 4
J721
J723
0 V
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
When '1', developing AC
bias is generated.
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
CHAPTER 6 IMAGE FORMATION SYSTEM
AC output 1000 Vpp
J732
The developing DC bias varies as
follows according to the DEV-DC-CNT
potential.
500V
image area
Non-image
area
Developing cylinder
3V
11V 12V
DEV-DC-CNT