CHAPTER 13 TROUBLESHOOTING
5
E004
Cause
Step
SSR
DC controller
PCB
6
E005
Cause
Step
Cleaning belt
Cleaning belt
detecting lever
DC controller
PCB
Sensor
7
E010
Cause
Step
DC controller
PCB
Main motor
(M1)
13-84
COPYRIGHT © 1999 CANON INC.
1
Replace the SSR. Is the problem
corrected?
1
Has the cleaning belt of the fixing
assembly been taken up?
2
Is the position of the cleaning belt
detection lever correct?
3
Is the cleaning belt sensor (PS7) normal?
(See the instructions on how to check
photointerrupters.)
1
Is the connector of the main motor
connected?
2
Does the voltage between J514-B5 (+)
and J514-B3 (-) on the DC controller PCB
change from 0 to about 5 V when the
Copy Start key is pressed?
Checks
Checks
Checks
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Yes/No
Action
YES
End.
NO
Replace the DC
controller PCB.
Yes/No
Action
YES
Replace the cleaning
belt with a new one.
NO
Correct the position of
the lever.
YES
Replace the DC
controller PCB.
NO
Replace the sensor.
Yes/No
Action
NO
Connect the connector.
NO
Replace the DC
controller PCB.
YES
Replace the main
motor.

Advertisement