The Pre-Exposure Lamp Fails To Turn On; The Scanning Lamp Fails To Turn On - Canon ImageRunner 600 Service Manual

Hide thumbs Also See for ImageRunner 600:
Table of Contents

Advertisement

72

The pre-exposure lamp fails to turn on.

Cause
Step
Pre-exposure
lamp PCB
DC controller
PCB
Pre-exposure
lamp PCB
73

The scanning lamp fails to turn on.

Cause
Step
Connector
Lamp
Relay PCB
Inverter PCB
DC controller
PCB
COPYRIGHT © 1999 CANON INC.
1
Select COPIER>1/O>IP in service mode.
Does bit 6 of address P017 change from
'0' to '1' when the Copy Start key is
pressed?
2
Set the meter to the 30 VDC range. Does
the voltage between J504-A1 (+) on the
DC controller PCB and GND change
from 0 to 24 V when the Copy Start key
is pressed?
1
Select COPIER>FUNCTION>MISC-
R>SCANLAMP in service mode. Does
the scanning lamp remain on for 3 sec
when the OK key is pressed?
2
Is the scanning lamp (LA1) mounted
correctly?
3
Measure the voltage of J1001-1 on the
inverter PCB. Is it 38 V?
4
Measure the voltage of J506-B11 on the
DC controller PCB. Does it change from
5 to 0 V when the control panel power
switch is turned on?
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
CHAPTER 13 TROUBLESHOOTING
Checks
Checks
Yes/No
Action
YES
Check the wiring from
the DC controller PCB
to the pre-exposure
lamp PCB; if normal,
replace the pre-
exposure lamp PCB.
NO
Replace the DC
controller PCB.
YES
Check the wiring from
the DC controller PCB
to the pre-exposure
lamp PCB; if normal,
replace the pre-
exposure lamp PCB.
Yes/No
Action
YES
Check the connector. It
may have poor contact.
NO
Disconnect the power
plug, and mount the
lamp correctly.
NO
Check the AC line up
to the relay PCB; if
normal, replace the
relay PCB.
YES
Check the wring; if
normal, replace the
inverter PCB.
NO
Check the wiring; if
normal, replace the DC
controller PCB.
13-111