Down Sequence Control

Part 2>Chapter 7>3.3
STBY
Main heater(H1)
Sub heater(H2)
Copying speed
Controlled to 200˚C
˚C
200
˚C
195
˚C
190
˚C
185
˚C
180
˚C
175
˚C
170
˚C
165
˚C
160
At 175˚C, dropped to
50 cpm.
At 170˚C, dropped to
40 cpm.
Related Service Mode
COPIER>OPTION>BODY>FIX-TMP1
(down sequence state temperature)
Set a relatively high temperature for users
who prefer priority on image quality, and a
relatively low temperature for users who prefer
priority on productivity.
COPYRIGHT © 2000 CANON INC.
Copy
Start key
ON
PRINT
60cpm
50cpm
Figure 8-302 Down Sequence
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
CHAPTER 8 FIXING SYSTEM
STOP
40cpm
Stopped
The sub heater is also turned
on to recover temperature.
At 200˚C, printing is resumed automatically.
At 165˚C, printing stopped.
Setting
50cpm
0
170˚C
1
175˚C
2
180˚C
3
185˚C
4
190˚C
5
195˚C
PRINT
60cpm
40cpm
Stop
Resume
165˚C
160˚C
175˚C
170˚C
165˚C
180˚C
175˚C
170˚C
185˚C
180˚C
175˚C
190˚C
185˚C
180˚C
195˚C
190˚C
185˚C
200˚C
8-13