CHAPTER 6 IMAGE FORMATION SYSTEM
2.

Controlling the Output to Suit the Environment (fuzzy control)

The pre-transfer charging current is controlled to an optimum value to suit the environment
(conditions identified based on data from the environment sensor).
Related Service Mode
COPIER>OPTION>BODY>FUZZY
(fuzzy control ON/OFF)
6-22
COPYRIGHT © 1999 CANON INC.
Low
humidity
Figure 6-305 Pre-Transfer Current Output Table
0: enable fuzzy control. (default)
1: low humidity mode. (The pre-transfer charging current is
2: normal humidity mode.
3: high humidity mode. (The pre-transfer charging current is
Selecting '1' through '3' makes the mechanism independent of
the environment sensor.
High
humidity
lower than the standard level.)
higher than the standard level.)
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.