Canon ImageRunner 600 Service Manual page 588

Hide thumbs Also See for ImageRunner 600:
Table of Contents

Advertisement

CHAPTER 13 TROUBLESHOOTING
4) Fit the potential sensor tester electrode (FY9-3041) to the potential sensor.
Caution:
When fitting the tester electrode to the potential sensor, take care so that the magnet of the
electrode will not come into contact with the potential sensor cover.
5) Connect the cable of the potential sensor tester electrode to the support metal plate (GND) of
the potential measurement PCB.
Caution:
Be sure not to bring the clip into contact with the sensor cover by keeping it sufficiently away
from the window of the sensor.
Potential sensor support plate
13-16
COPYRIGHT © 1999 CANON INC.
Potential sensor
tester electrode
Potential sensor
Figure 13-C201
Cable
Figure 13-C202
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.