Fixing System; Position Of The Fixing Assembly Inlet Guide - Canon ImageRunner 600 Service Manual

Hide thumbs Also See for ImageRunner 600:
Table of Contents

Advertisement

CHAPTER 13 TROUBLESHOOTING
E.

Fixing System

1
Points to Note When Mounting the Fixing Heater
1. Do not touch the surface of the heater.
2. Mount the fixing heater so that its terminal with the longer wire is toward the front. (This
applies to both heaters.)
3. Mount the main heater (760 W for the 15A model; 850 W for the 20 A model) on the right side
of the fixing assembly (viewing from the front) and the sub heater (400 W for the 15A model;
360 W for the 20A model) to the left side.
4. Connect the fastons of the heater harness at the rear. (Connect the right side to the main heater,
and the top side to the sub heater when viewing from the rear.)
2

Position of the Fixing Assembly Inlet Guide

Points to Note When Adjusting in the Field
• The inlet guide must be mounted as shown in the diagram.
• The inlet guide must lower when the solenoid (SL1) turns on.
• The inlet guide must be level so that the difference in height between its front and rear must be
within 0.5 mm.
• The inlet guide must be adjusted for height by loosening the fixing screw on the "height adjust-
ing support plate."
13-34
COPYRIGHT © 1999 CANON INC.
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.