E014; E015; E019 - Canon ImageRunner 600 Service Manual

Hide thumbs Also See for ImageRunner 600:
Table of Contents

Advertisement

CHAPTER 13 TROUBLESHOOTING
10

E014

Cause
Step
DC controller
PCB
Pickup motor
(M2)
11

E015

Cause
Step
DC controller
PCB
Pickup motor
(M2)
12

E019

Cause
Step
Waste toner
Waste toner case
mount
Connect the
connector
Waste toner
case sensor
DC controller
PCB
13-86
COPYRIGHT © 1999 CANON INC.
1
Is the connector of the pickup motor
connected?
2
Does the voltage between J513-A3 (+)
and J513-A1 (-) on the DC controller
PCB change from 0 to about 5 V when
the Copy start key is pressed?
1
Is the connector of the pickup motor
connected?
2
Does the voltage between J513-A3 (+)
and J513-A1 (-) on the DC controller
PCB change from 0 to about 5 V when
the Copy Start key is pressed?
1
Is the waste toner case full?
2
Is the movement of the waste toner mount
smooth?
3
Is the connector (J514) on the DC
controller PCB connected securely?
4
Replace the waste toner sensor (PS19). Is
the problem corrected?
Checks
Checks
Checks
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Yes/No
Action
NO
Connect the connector.
NO
Replace the DC
controller PCB.
YES
Replace the pickup
motor.
Yes/No
Action
NO
Connect the connector.
NO
Replace the DC
controller PCB.
YES
Replace the pickup
motor.
Yes/No
Action
NO
Dispose of the waste
toner.
NO
Correct the movement.
NO
Connect the connector
securely.
YES
Check the connection
of the cable up to the
DC controller PCB; if
normal, replace the
waste toner sensor
(PS19).
NO
Replace the DC
controller PCB.

Advertisement

Table of Contents
loading

Table of Contents