C.

Image Formation System

1

Routing the Primary Charging Assembly Grid Wire

See Chapter 6> VII.C. "Charging Wires."
2

Routing the Charging Assembly Charging Wires

See Chapter 6> VII.C. "Charging Wires."
3

Mounting the Drum Cleaning Blade

See Chapter 6> VII.F. "Drum Cleaner Unit."
4.

Mounting the Developing Blade

See Chapter 6> VII.E. "Developing Assembly."
5

Replacing the Potential Sensor/Potential Control PCB

1) Check to make sure that the data lamp on the control panel is off, and turn off the main
power switch.
2) Disconnect the power plug.
Caution:
The copier remains powered as long as the power plug is connected to the power outlet even
after the main power switch is turned off. Be sure to disconnect the power plug.
3) Replace the potential sensor/potential control PCB.
Caution:
The potential sensor and the potential control PCB are adjusted as a pair. Be sure to replace
both of them if either of them must be replaced.