10) Connect the power supply unit to the
power plug, and check to make sure that
LED1 [14] (green) on the PCB of the con-
troller turns on.
11) Execute RAM clear. Set the bits of the
DIP switch [15] (SW2) on the PCB of the
controller as shown in the following table,
and push the push switch [16] (SW4) so
that LED5 [17] (red) turns on.
SW2 bits
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
COPYRIGHT © 1999 CANON INC.
Setting
OFF
OFF
ON
ON
OFF
OFF
See step 8).
OFF
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
CHAPTER 11 INSTALLATION