9.1 Position of the Fixing Inlet Guide Solenoid (SL1)
Adjust the position of the solenoid using the screw [1] so that the guide will lower 1.8 mm
when the solenoid turns on.
Guide
1.8mm
[1]
Solenoid (SL1)
Figure 13-D210