CHAPTER 11 INSTALLATION
3) Disconnect the shorting connector from
the control panel cable; lead the cable of
the control card through the wire saddle,
and connect it to the connector. (You will
not be using the shorting connector.)
4) Secure the control panel in place to the
copier.
5) Remove the protective sheet from the con-
trol panel label of the control card.
6) Attach the control panel label to the con-
trol card.
7) Connect the connectors and mount the
covers that have been disconnected or re-
moved.
8) Turn on the copier's main power switch
and the control panel switch; then, check
the operation of the control card.
11-26
COPYRIGHT © 1999 CANON INC.
Shorting connector
Wire saddle
Remove
Connect
Figure 11-411
Control panel label
Figure 11-412
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.