Canon ImageRunner 600 Service Manual page 102

Hide thumbs Also See for ImageRunner 600:
Table of Contents

Advertisement

2.
Removing the Inverter PCB
1) Remove the rear cover.
2) Remove the two screws [1], and discon-
nect the seven connectors [2]. While re-
moving the hook of the mounting plate
upward, remove the inverter control as-
sembly [3].
COPYRIGHT © 1999 CANON INC.
CHAPTER 3 ORIGINAL EXPOSURE SYSTEM
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A
[2]
[3]
[1]
[2]
Figure 3-C503
Inverter unit
Hook (left)
Inverter unit
Figure 3-C504
[2]
[2]
[1]
Hook (right)
3-29