CHAPTER 13 TROUBLESHOOTING
23
E066
Cause
Step
Connector
Connector
Pre-transfer
charging wire,
Cleaning home
position
detecting switch
(MSW3)
Pre-transfer
charging wire
cleaner motor
(M7)
DC controller
PCB
13-91-2
COPYRIGHT © 2000 CANON INC.
1
Are the connectors of the pre-transfer
charging assembly connected securely?
2
Is the connector (J504) on the DC
controller PCB connected securely?
3
Is the mounting of the pre-transfer
charging wire cleaner home position
detecting switch and the connection of the
cable normal?
4
Replace the pre-transfer charging wire
cleaner motor (M7). Is the problem
corrected?
Checks
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Yes/No
Action
NO
Connect the connectors
securely.
NO
Connect the connector
securely.
NO
If normal, replace
detecting switch.
YES
End.
NO
Replace the DC
controller PCB.