CHAPTER 11 INSTALLATION
Caution:
1. If SW5-4 of the DIP switch on the
controller is set to OFF, group control
is disabled, and the following is indi-
cated:
Figure 11-C608
2. If the copier's memory is used for ID
input (using the copier on its own), the
exiting ID Nos. may be used for the
controller. Perform the following:
! Drawing the ID Nos.
a) Set the DIP switch (SW1) of the controller
as follows:
b) Press the switch SW4 on the controller.
In response, LED5 turns on momentarily.
c) Check LED5; it should turn on to indicate
that the data has been drawn.
Otherwise, LED5 will flash. Press the
switch SW4 once again, and see that
LED5 turns on.
The copier cannot discharge paper while
data is being drawn.
d) Set the DIP switch (SW1) on the control
as follows (LED5 should turn off):
11-46
COPYRIGHT © 1999 CANON INC.
bit
SW1
1,2
Table 11-C602
LED1
LED2
LED1
LED2
LED3
SW2
LED4
LED5
LED6
LED5
6
1
6
1
SW1 ON
SW5 ON
SW1-3
SW1-2
SW1-1
Figure 11-C609
bit
SW1
1, 2, 3
Table 11-C603
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Position
ON
3
OFF
LED3
SW3
JA1
JB2
JA2
JB1
SW4
SW4
Position
OFF