I . SELECTING THE SITE
The site of installation must meet the following conditions; if possible, pay a visit to the user's
before the delivery of the copier.
1. There must be a power outlet providing voltage as rated (+10%, -15%) and a means of ground-
ing the copier.
2. The temperature and the humidity of the site must be 15°C to 30°C and 5% to 80%, respec-
tively. In particular, avoid areas near water faucets, water boilers, humidifiers, and refrigera-
tors.
3. The area must not be near sources of fire, and the site must not be subject to dust or ammonium
gas. If direct sunshine is expected, provide curtains.
4. The level of ozone generated by the copier will not harm the health of the people working
around it. However, some individuals may find the odor unpleasant, and it is important to make
sure that the room is ventilated well.
5. The area must ensure that the copier's feet will remain in contact and the copier will remain
level.
6. The area must allow adequate space for operating the copier. (The copier must be at least 10 cm
away from any wall.)