D.

Protective Functions

The copier is designed to automatically stop the output of the DC power supply as soon as the
overcurrent protective mechanism turns on.
If an overcurrent is detected by the overcurrent detection circuit A, outputs [1] and [2] are
stopped; this is to prevent malfunction of the copier, as output [1] is used by the logic system.
If the overcurrent detection circuit B detects an overcurrent, output [2] is stopped.
DC power supply PCB
Converter
circuit 1
3.3V/5V/+8V
-8V/12V/15V
Converter
circuit 2
24V/38V
Sequence
control
circuit
Figure 9-505 Protective Function Block Diagram
Detection by
Overcurrent
detection circuit A
Overcurrent
detection circuit B
COPYRIGHT © 1999 CANON INC.
CHAPTER 9 EXTERNALS/AUXILIARY MECHANISMS
Overcurrent
protection
circuit 1
Overcurrent
protection
circuit 2
Copier operation
Stops outputs [1] and [2]
from the DC power supply
PCB.
Stops output [2] from the
DC power supply PCB.
Table 9-504 Protective Functions
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Output [1]
5V
12V
3.3V
+8V
-8V
15V
Output [2]
38V
24V
Overcurrent
J1701
detection signal 2
5
Overcurrent detection signal 1
4
Outputs [1] and [2] are stopped.
Output [2] is stopped.
Turn off the main power switch, and remove the
cause; then, leave the machine alone for about 3
min, and turn on the main power switch.
Remove the cause, and turn off and then on the
control panel power switch.
Relay PCB
Overcurrent
detection
circuit A
Overcurrent
detection
circuit B
Resetting
9-17