CHAPTER 7 PICK-UP/FEEDING SYSTEM
4) Remove the screw [3], and detach the
duplexing unit right fixing assembly [4];
then, remove the two screws [5] at the
rear, and detach the right grip plate [6].
Caution:
When mounting the right grip plate, be
sure that the boss on the grip plate is in
the hole of the side plate.
5) Remove the screw [7], and detach the
horizontal registration sensor [8].
7-88
COPYRIGHT © 1999 CANON INC.
[6]
[5]
[4]
Figure 7-F825
[8]
Figure 7-F826