B.

BD Unit

1.

Removing the BD Unit

1) Open the front cover.
2) Slide out the process unit. (See Figures 6-
D701 through -D702.)
3) Remove the three screws [1], and discon-
nect the three connectors [2]; then, re-
move the fan (primary charging, scanner
cooling, polygon mirror) unit [3].
4) Remove the screws [4], and slide out the
BD unit [5] to the front.
Caution:
Be sure to mark the position of the screw
[4] with a scriber before loosening it.