2.4.13 Adjusting the Position for the Multifeeder Pickup Latch Solenoid (SL6)

Adjust the solenoid in the direction of A to adjust so that the gap between the shutter [1]
and the shutter plate [2] is 0.4 ±0.2 mm when the solenoid is pulled.
COPYRIGHT© 2001 CANON INC.
A
F06-204-16
[1]
F06-204-17
2000 2000 2000 2000
CANON iR8500/7200 REV.1 AUG. 2001
CHAPTER 6 TROUBLESHOOTING
[2]
6-31