B.
Parts Associated with the
Process Unit
1.

Removing the Pre-Exposure

Lamp Unit

1) Open the front cover.
2) Slide out the process unit.
Caution:
Cover the drum with A3 paper or the like
when you have slid out the process unit.
3) Disconnect the connector [1], and remove
the two screws [2]; then, detach the pre-
exposure unit [3].
4) Remove the three screws [4], and detach
the pre-exposure holder [5]; then, detach
the pre-exposure lamp [6].
COPYRIGHT © 1999 CANON INC.
CHAPTER 6 IMAGE FORMATION SYSTEM
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
[2]
[1]
Figure 6-B701
[5]
[4]
Figure 6-B702
[6]
Figure 6-B703
[3]
6-55