Canon ImageRunner 600 Service Manual page 840

Hide thumbs Also See for ImageRunner 600:
Table of Contents

Advertisement

CHAPTER 13 TROUBLESHOOTING
Code
• The deck main motor (M101) is faulty.
E043
• The side deck driver PCB is faulty.
• The DC controller PCB is faulty.
• The horizontal registration sensor
(PS18) is faulty.
• The horizontal registration motor (M15)
is faulty.
E051
• The DC controller PCB is faulty.
• The manual tray cover open/closed
detecing switch (MSW5) is faulty.
• The primary charging wire cleaner
motor (M8) is faulty.
• The primary charging wire cleaner
E060
home position detecting switch
(MSW4) is faulty.
• The DC controller PCB is faulty.
• The transfer/separation charging wire
cleaner motor (M9) is faulty.
• The transfer/separation charging wire
E063
cleaner home position detecting switch
(MSW6) is faulty.
• The DC controller PCB is faulty.
• The primary charging assembly is faulty.
• The HV-DC PCB is faulty.
E065
• The wiring is faulty (short circuit, open
circuit).
• The pre-transfer charging wire cleaner
motor (M7) is faulty.
• The pre-transfer charging wire cleaner
E066
home position detecting switch
(MSW3) is faulty.
• The DC controller PCB is faulty.
• The HV-DC PCB is faulty.
E067
• The HV-AC PCB is faulty.
• The wiring is faulty (short circuit, open
circuit).
• The HV-DC PCB is faulty.
• The HV-AC PCB is faulty.
• The separation charging assembly is
E068
faulty.
• The wiring is faulty (short circuit, open
circuit).
• The HV-DC PCB is faulty.
• The transfer charging assembly is faulty.
E069
• The wiring is faulty (short circuit, open
circuit).
13-252
COPYRIGHT © 2000 CANON INC.
Cause
CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.
Description
• No PLL lock signal (DMPLK) arrives
for 2 sec or more after the input of the
PLL lock signal (DMPLK).
• The home position signal is not detected
in 5 sec while the horizontal registration
motor (M15) drive signal is being
generated.
• The home position is not detected within
60 sec after wire cleaning has been
started.
• The home position is not detected within
60 sec after wire cleaning has been
started.
• The high-voltage to the primary charging
assembly is faulty (leakage).
• The home position cannot be detected
within 60 sec after wire cleaning has
been started.
• Of the primary high-voltage, pre-transfer
high-voltage, transfer high-voltage, and
separation high-voltage, a fault is found
in two or more at the same time.
• The high-voltage output to the separation
charging assembly has a fault (leakage).
• The high-voltage to the transfer charging
assembly has a fault (leakage).

Advertisement