CHAPTER 6 IMAGE FORMATION SYSTEM
8) Remove the C-ring [16], washer [17],
pressure roll [18], seal [19], washer [17],
butting roll [20], C-ring [16], and bearing
[21]; the, remove the two screws [22], and
detach the bushing [23] and then the de-
veloping sleeve [24].
Caution:
Do not leave fingerprints or oil on the
surface of the developing cylinder. Wipe
off any with lint-free paper. (Do not use
solvent.)
Points to Note When Mounting
the Developing Cylinder
Both front and rear sides of the develop-
ing assembly and the developing cylin-
der are equipped with a magnetic seal
plate.
When mounting the developing cylin-
der, take care not to bring the magnetic
seal plate into contact with the surface of
the cylinder to avoid damage.
6-74
COPYRIGHT © 2000 CANON INC.
[24]
[23]
[21]
[16]
[20]
Figure 6-E712
Magnetic seal plate
Figure 6-E713