Table 50 Error codes (part code 6005) (continued)
Part
Error
Code
Number
6005
68893
6005
68894
6005
68895
6005
68899
6005
68900
6005
75030
6005
78001
6005
78002

Part code 6007

Table 51 Error codes (part code 6007)
Part
Error
Code
Number
6007
5074
6007
6000
6007
6002
Error Message
The operation failed, because the
following program products were not
installed in the RCU.
Continuous Access Synchronous
External Storage Access Manager
The operation failed, because the
quorum disk registered in the specified
quorum disk ID was not registered in
the quorum disk ID of RCU, or it was
registered in the other quorum disk ID.
The operation failed, because of one
of following reasons.
Specified the other program product
for the pair of Continuous Access
Synchronous.
Specified the other program product
for the pair of External Storage
Access Manager.
The operation failed, because a quorum
disk was not registered in the specified
quorum disk ID.
The operation failed, because the
specified quorum disk ID was different
from the one used by the specified pair.
The specified port or the initiator port
used by the MCU cannot be used
because the port has no access right
for a resource group.
The operation failed, because the
current microcode version does not
support the capacity of the specified
M-VOL.
The operation failed, because the
current microcode version does not
support the capacity of the specified
R-VOL.
Error Message
Continuous Access Synchronous, External
Storage Access Manager, or Continuous
Access Synchronous Z is not installed.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
Recommended Action
Install the necessary
program products in the
RCU.
Confirm the quorum disk ID,
serial number of RCU, and
quorum disk.
Confirm the program
product of the specified pair.
Confirm the quorum disk ID
status.
Confirm the quorum disk ID
of the specified pair.
Verify the available ports.
Check the microcode version
of the storage system.
Check the microcode version
of the storage system.
Recommended Action
Install Continuous Access Synchronous,
External Storage Access Manager, or
Continuous Access Synchronous Z.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Severity Level
W
W
W
W
W
W
W
W
Severity
Level
W
E
E
Part code 6007