Setting speed-dependent current limitation for motors without a bend in the commutation
characteristic
Figure 10-76 Example of a motor rating plate
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
= Motor rating plate data
= Permissible limit values
= Application point for speed-dependent current
limitation
= Maximum operating speed
I20 = 1.2 × I2
ac.maher.co.ir
Descriptions of functions
10.21 Speed-dependent current limitation