Commissioning
8.3 Commissioning using the AOP30 operator panel
8.3.2
Status after commissioning
LOCAL mode (control via operator panel)
● You switch to LOCAL mode by pressing the "LOCAL/REMOTE" key.
● Control (ON/OFF) is carried out via the "ON" and "OFF" keys.
● You can set the setpoint using the "Increase" and "Decrease" keys or by entering the
appropriate numbers on the operation screen using the numeric keypad.
8.3.3
Resetting parameters to factory settings
The factory settings represent the defined original status of the unit on delivery.
Resetting the parameters to the factory settings means that all the parameter settings made
since the system was delivered are reset.
Setting the parameter filter to "Parameter reset"
<MENU> <Commissioning/Service> <OK> <Device commissioning> <OK> <30: Parameter
Reset> <OK>
Restoring all parameters to their factory settings
All of the unit parameters are reset to their factory settings. The AOP30 is powered down
and back up again during this process.
272