Operation
9.2 Parameterizing using the BOP20 (Basic Operator Panel 20)
Name
Hot swapping
Key operation
Overview of important parameters (refer to the SINAMICS DCM List Manual)
All drive objects
● p0005 BOP status display selection
● p0006 BOP status display mode
● p0013 BOP user-defined list
● p0971 Drive object, save parameters
Drive object, Control Unit (CU_DC)
● r0002 Control Unit status display
● p0003 BOP access level
● p0004 BOP display filter
● p0007 BOP backlighting
● p0008 BOP drive object selection
● p0009 Device commissioning, parameter filter
● p0011 BOP password input (p0013)
● p0012 BOP password confirmation (p0013)
● r0019 CO/BO: Control word, BOP
● p0977 Save all parameters
346
The BOP can be unplugged and plugged while energized.
The ON and OFF keys have a function.
When unplugging, the drives are stopped.
After plugging, the drives must be switched on again.
The ON and OFF keys have no function
Unplugging and plugging has no effect on the drives.
The following applies to the "P" and "FN" keys:
When used in a combination with another key, "P" or "FN" must be pressed before the
other key.