NOTICE
Destruction of the encoder due to an incorrect supply voltage
The encoder supply voltage can be assigned as 5 V or 24 V. The encoder may be
destroyed if you enter the wrong parameters.
• Select the appropriate motor supply voltage.
7.2.3.4
X521/X531 alternative encoder system interface
Table 7- 9
X521/X531 alternative encoder system interface
Pin
X521
1
2
3
4
5
6
7
8
1
X531
2
3
4
5
6
7
8
Max. connectable cross-section: 1.5 mm
Measuring current via the temperature sensor connection: 2 mA
When unipolar HTL encoders are used, A*, B*, and R* on the terminal block must be jumpered with M_Encoder (X531)
Because the physical transmission properties are more robust, the bipolar connection should always be used. The
1)
unipolar connection should only be used if the encoder type does not output push-pull signals.
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
Designation
A
A*
B
B*
R
R*
CTRL
M
P_encoder 5 V/24 V
M_Encoder
- Temp
+ Temp
Clock
Clock*
Data
Data*
2
ac.maher.co.ir
Additional system components
7.2 Sensor Module Cabinet-Mounted SMC30
Technical specifications
Incremental signal A
Inverse incremental signal A
Incremental signal B
Inverse incremental signal B
Reference signal R
Inverse reference signal R
Control signal
Ground
Encoder supply
Ground, encoder supply
Temperature sensor KTY84-1C130
Temperature sensor KTY84-1C130
SSI clock
Inverse SSI clock
SSI data
Inverse SSI data
.
1)