Download Print this page

Siemens SINAMICS DCM Manual page 183

Dc converter
Hide thumbs Also See for SINAMICS DCM:

Advertisement

Connecting
6.9 Assignment of terminals and connectors
Parallel interface
Table 6- 41
Connector assignment, parallel interface
Connector
Pin
X165, X166
1
2
3
4
5
6
7
8
-
Standard CUD, Advanced CUD module
Terminal assignment for option G63
The technical data for terminals X177_1, X177_2 and X177_5 corresponds to the
specifications for terminal X177 on the Connector Board in the version without option G63,
see Table 6-36 Assignment, terminal X177 X177 (Page 176).
Table 6- 42
Assignment of the terminals on the Terminal Module Cabinet (TMC) (overview)
Terminal
Function
X177_1, X177_2
1st terminal block (X177_1)
1, 2
AI 3 +, AI 3 -
3, 4
AI 4 +, AI 4 -
5, 6
AI 5 +, AI 5 -
7, 8
AI 6 +, AI 6 -
9, 10
24 VDC
11, 12, 13, 14
DI 0, 1, 2, 3
15, 16, 17, 18
DI/DO 4, 5, 6, 7
19, 20, 21 22
DO 0, 1, 2, 3
23, 24
M
25, 26
AI 0 +, AI 0 -
27, 28
AI 1 +, AI 1 -
29, 30
AI 2 +, AI 2 -
184
Signal name
Technical specifications
SYNC_P
Synchronization +
SYNC_N
Synchronization -
CANH
CAN +
-
Reserved, do not use
-
Reserved, do not use
CANL
CAN -
-
Reserved, do not use
-
Reserved, do not use
Shield
Permanently connected to ground
Analog input 3
Analog input 4
Analog input 5
Analog input 6
24 V supply (output)
Digital input 0, 1, 2, 3
Digital input/output 4, 5,
6, 7
Digital output 0, 1, 2, 3
Ground, digital
Analog input 0, main
setpoint
Analog input 1
Analog input 2
ac.maher.co.ir
Description
See X177.1 and 2
See X177.3 and 4
See X177.5 and 6
See X177.7 and 8
24 VDC, short-circuit proof
Max. load 200 mA (terminals 9, 10, 57, 58, 59 and
60 combined),
internal supply to digital ground and analog ground
See X177.11, 12, 13, 14
See X177.15, 16, 17, 18
See X177.19, 20, 21, 22, 23, 24
See X177.25 and 26
See X177.27 and 28
See X177.29 and 30
SINAMICS DCM DC Converter

Advertisement

loading