Additional system components
7.5 Terminal Module TM150
7.5.3.3
X524 Electronics power supply
Table 7- 40
The maximum cable length that can be connected is 10 m.
Note
The two "+" or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE-CLiQ node.
7.5.3.4
X531-X536 temperature sensor inputs
Table 7- 41
X531-X536: Temperature sensor inputs
Terminal
Function
1x2- / 2x2-wire
1
+ Temp
(channel x)
2
- Temp
(channel x)
3
+ Temp
(channel y)
4
- Temp
(channel y)
Measuring current via temperature sensor connection: Approx. 0.83 mA
248
X524: Electronic power supply
Terminal
Designation
+
Electronic power supply
+
Electronic power supply
M
Electronics ground
M
Electronics ground
Function
3 and 4-wire
+
(channel x)
-
(channel x)
+ I
c
(constant current, positive
channel x)
- I
c
(constant current, nega-
tive
channel x)
ac.maher.co.ir
Technical specifications
Voltage: 24 VDC (20.4 V – 28.8 V)
Current consumption (max./typ.): 0.5 A /
0.1 A
Max. current via jumper in connector:
20 A
Technical specifications
Temperature sensor connection for sensors with
1x2 wires
Connection of the 2nd measurement cable for
sensors with 4-wires
Temperature sensor connection for sensors with
1x2 wires
Connection of the 1st measurement cable for
sensors with 3 and 4-wires.
Temperature sensor connection for sensors with
2x2, 3 and 4-wires