Hide thumbs Also See for SINAMICS DCM:

Advertisement

4. The "Insert slot" button can be used to create a new setpoint slot for the SINAMICS DCM
drive object.
Figure 10-23 Insert new slot
5. Assign the setpoint slot the type "direct data exchange".
6. Select the publisher DP address in the "PROFIBUS address" column.
All PROFIBUS DP slaves are listed here from which actual value data can be requested.
It also provides the possibility of sharing data via direct data exchange within the same
drive group.
7. The "I/O address" column displays the start address for every DO.
Select the start address of the DO data to be read. This is 200 in the example.
If the complete data of the publisher is not read, set this via the "Length" column. You
may also offset the start address for the request so that data can be read out in the
middle of the DO telegram.
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
ac.maher.co.ir
Descriptions of functions
10.4 Communication via PROFIBUS DP
449