〈2〉Adjust the rated device currents
Note
The US rating must be set at p50067 for Base Drives (type 6RA80xx-2xxxx) manufactured in
North America.
The rated armature DC current for the device must be adjusted by setting p50076[0] (in %)
or p50067 if:
Maximum armature current < 0.5 × rated armature DC current for the device
The rated field DC current for the device must be adapted by setting p50076[1] (in %) if:
Maximum field current < 0.5 × rated field DC current for the device
〈3〉Adjust to the actual device supply voltage
p50078[0]
p50078[1]
〈4〉Enter the motor data
The motor data, as specified on the motor rating plate, must be entered in the following
parameters (see also the sections titled
"Speed-dependent current limitation"
Figure 8-1
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
Rated input voltage for converter armature (in volts)
Rated input voltage for converter field (in volts)
):
Example of a rating plate