Download Print this page

Siemens SINAMICS DCM Manual page 396

Dc converter
Hide thumbs Also See for SINAMICS DCM:

Advertisement

Bit
Meaning
6
1 = Switching on inhibited active
7
1 = Alarm present
8
1 = Speed setpoint/actual-value deviation in tolerance
9
1 = Control requested
10
1 = n comparison value reached or exceeded
11
1 = Torque limit not reached
12
1 = Open holding brake
13
Reserved
3)
to
15
ZSW1 BM is formed via binector-connector converter (BI: p2080[0...15], inversion: p2088[0].0...p2088[0].15).
1)
The drive object is ready for acceptance.
2)
Interconnection is not disabled.
3)
ZSW2_BM (status word 2, metal industry)
See function diagram [2429].
Table 10- 16 Status word 2, metal industry (ZSW2 BM)
Bit
Meaning
0
Reserved
1)
to
4
5
1 = Alarm class bit 0
6
1 = Alarm class bit 1
7
Reserved
8
Reserved
9
1 = Speed setpoint limited
10
1 = Upper torque limit reached
11
1 = Lower torque limit reached
12
1 = Encoderless operation because of fault
13
1 = SS1 delay time active in drive
14
STO active in drive
15
Controller sign of life toggle bit
Interconnection is not disabled.
1)
NACT_A (speed setpoint A (16-bit))
● Actual speed value with 16-bit resolution.
● The speed actual value is normalized in the same way as the setpoint (see NSET_A).
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
2)
ac.maher.co.ir
Descriptions of functions
10.3 Communication according to PROFIdrive
Interconnection parameter
p2080[6] = r0899.6
p2080[7] = r2139.7
p2080[8] = r2197.7
p2080[9] = r0899.9
p2080[10] = r2199.1
p2080[11] = r1407.7
p2080[12] = r0899.12
-
Interconnection parameter
-
p2081[5] = r2139.11
p2081[6] = r2139.12
-
-
p2081[9] = r1407.11
p2081[10] = r1407.8
p2081[11] = r1407.9
p2081[12] = r1407.13
p2081[13] = r53110.1
p2081[14] = r53110.0
p2081[15] = r2093.15
397