Download Print this page

Siemens SINAMICS DCM Manual page 395

Dc converter
Hide thumbs Also See for SINAMICS DCM:

Advertisement

Descriptions of functions
10.3 Communication according to PROFIdrive
Bit
Meaning
Reserved (when p0922 = 20)
13
Reserved
14
Motor rotates forward
(n_act ≥ 0)
15
Reserved
(when p0922 = 1 or 352)
CDS display
(when p0922 = 20)
ZSW2 (status word 2)
See function diagram [2454].
Table 10- 14 Status word 2 (ZSW2)
Bit
Meaning
0
1 = Drive data set selection DDS effective, bit 0
1
1 = Drive data set selection DDS effective, bit 1
2
Reserved
3
Reserved
4
Reserved
5
1 = Alarm class bit 0
6
1 = Alarm class bit 1
7
Reserved
8
Reserved
9
Reserved
10
1 = Enable pulses
11
Reserved
to
15
ZSW1_BM (status word 1, metal industry)
See function diagram [2428].
Table 10- 15 Status word 1, metal industry (ZSW1 BM)
Bit
Meaning
0
1 = Ready to switch on
1
1 = Ready
2
1 = Enable operation 1
3
1 = Fault present
4
0 = Coast to stop active (OFF2)
5
0 = Quick stop active (OFF3)
396
Explanation
1
Motor rotates forward (n_act ≥ 0)
0
Motor does not rotate forward (n_act < 0)
1
CDS selection bit 0 selected
0
CDS selection bit 0 not selected
1)
ac.maher.co.ir
Interconnection parameter
p2081[0] = r0051.0
p2081[1] = r0051.1
-
-
-
p2081[5] = r2139.11
p2081[6] = r2139.12
-
-
-
p2081[10] = r0899.11
-
Interconnection parameter
p2080[0] = r0899.0
p2080[1] = r0899.1
p2080[2] = r2811.0
p2080[3] = r2139.3
p2080[4] = r0899.4
p2080[5] = r0899.5
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
Parameter
BO: r2197.3
BO: r0836.0