Dc converter
Hide thumbs Also See for SINAMICS DCM:

Advertisement

Version:
Bus address:
Name:
Note
For a download, the bus address assigned here is transferred to the device, but is not
transferred to parameter p918.
To keep p918 consistent with the project, after a "Load to target device" a "Load to PG" must
still be performed – and must be repeated after every change to p918 using BOP20 or
AOP30.
Note
A second CUD for expanding the computing capacity is created in the STARTER as an
independent device, type "Sinamics DCM Standard (Advanced) CUD [2]".
Explanation: "[2]" is the SINAMICS nomenclature for indexed data. In this case, it is used as
a name - independent of any language for a second CUD inserted in the right-hand slot.
⇒ Click Insert
The selected drive unit is displayed in the project wizard preview window.
Figure 8-14
⇒ Click Continue >
A summary of the project is displayed.
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
8.4 Commissioning with the STARTER commissioning tool
actual version
The corresponding drive bus address (the default is 126)
Any desired name can be entered in the name box
Inserting a drive unit