Commissioning
8.2 Commissioning using the BOP20 operator panel
8.2
Commissioning using the BOP20 operator panel
8.2.1
Preconditions
SINAMICS basics
If you are not yet familiar with SINAMICS basics (parameters, drive objects, BICO
technology, and so on), please read "Basics" in the section titled "Operation" before starting
commissioning.
BOP20 operator panel
If you are not yet familiar with the BOP20 operator panel, please read "Assigning parameters
using the BOP20" in the section titled "Operation" before starting commissioning.
Notation of the parameters
Expressed in full, a parameter consists of
the drive object + parameter number + index, with the following notation:
(oo)pxxxxx[ii]
(oo)pxxxxx
To make these easier to read, in this chapter the drive object specification has been omitted
from all parameters belonging to the "automatic speed control" drive object (= drive object 2).
For example, the specification p50076[1] refers to parameter (2)p50076[1] (= drive object 2,
parameter 50076, index 1).
8.2.2
Commissioning steps
Note:
Parameters with [D] are data-set dependent. Commissioning must be carried out for each
data set.
〈1〉Access authorization
In order to be able to set the access authorization, drive object 1 (DO1) must be activated at
the BOP20, see Chapter 9, Section, Displaying and operation using the BOP20.
Access level
(1)p0003 = 1
(1)p0003 = 2
(1)p0003 = 3
260
for indexed parameters
for non-indexed parameters
Standard
Advanced
Expert
ac.maher.co.ir
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001