Commissioning
8.4 Commissioning with the STARTER commissioning tool
Entering the actual value source
Figure 8-22
"Encoder 1" is the encoder evaluation on the CUD.
"Encoder 2" is the evaluation of an optional encoder using SMC30
⇒ Enter the type of tachometer or other actual value source. The drive cannot be operated if
no selection is made.
⇒ Enter the reference speed. For display on the AOP30 or to transfer the speed variables via
PROFIBUS, the physical speed at 100 % is specified here.
⇒ Click Continue >
Encoder data - analog tachometer
⇒ Enter the tachometer voltage at maximum speed.
⇒ Click Next >